09.7 House Extension - Section Annotation

Section with No annotation above


Section with Annotation above





Generally sections and detail views have the most 2D work so once we finish these theres not much more to go. In this post we convert the defalt revit section into a more presentable section, do to this we add;
- Wide Dashed drafting lines for DPM and DPC
- Repeating detail for block work joints in section
- Filled region for the foundation trench infill(connects with the hardcore in the base of the floor slab)
-Learn how to import autocad hatch patterns that are not available in revit, some good download sites are http://www.cadcorner.ca/hatch.php and http://www.autocadhatch.com/
- Wide drafting lines for the steel lintel
- Thin drafting lines for the X inside of the cut ceiling joist and rafters
- Spot elevation makers
- Insulation tool for roof insulation
- Splitting the section marker lines
- Text notes and Leaders

Note: don't move the section markers in plan after you place the annotation or it will get out of sync with the 3D objects ( the last thing i show in the video)

Below is the text notes that i use in the video, you can copy and paste them from here if your following along,
Warning you must proof read them, check they comply with the latest local building regulations and all structural specification are check by your structural engineer, i don not take responsibility if you reuse these notes on a live project.

FOUNDATIONS CONSTRUCTION:

CONCRETE STRIP FOUNDATIONS ARE TO BE PROVIDED TO ALL NEW EXTERNAL WALLS. MINIMUM SIZE TO BE 900x300mm FOR CAVITY WALLS, ON 50 mm BLINDING. BUT SIZES, DEPTH, CONCRETE MIX AND STEEL REINFORCEMENT IF REQUIRED IN FOUNDATIONS TO BE AS INSTRUCTED BY STRUCTURAL ENGINEER FOLLOWING EXAMINATION OF SITE CONDITIONS.
 
NEW EXTERNAL RISING WALL CONSTRUCTION:

100mm SOLID BLOCK (TO IS 20: PART 1 : 1987) TO EXTERNAL AND INTERNAL LEAFS OF CAVITY WALLS WITH 100mm CONCRETE BACKFILL WITH STAINLESS STEEL DOUBLE TRIANGULAR WALL TIES (TO IS 269: 1986) TO MANUFACTURERS INSTRUCTIONS,


ALL BLOCKWORK SHALL BE OF NATURAL AGGREGATE AND SHALL BE BEDDED AND JOINTED IN GAUGED MORTAR AND PROPERLY BONDED AT INTERSECTIONS AND ANGLES.

GROUND FLOOR CONSTRUCTION:

150mm POWERFLOATED CONCRETE SLAB ON
SELECTED INSULATION TO CONFORM WITH PART L OF THE BUILDING REGULATIONS 2005 ON
1000 GAUGE POLYTHENE DPM WITH LAPPED & SEALED JOINTS, BY WELTING AND TAPING IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS, ON 50mm SAND BLINDING ON 150mm MINIMUM WELL COMPACTED CLEAN HARDCORE. HARDCORE TO BE CONSOLIDATED IN LAYERS NOT EXCEEDING 150mm. DPM TO BE CONTINUOUS WITH DAMP PROOF COURSE TO WALLS.


EXTERNAL WALL CONSTRUCTION:

100mm SOLID BLOCK (TO IS 20: PART 1 : 1987) TO EXTERNAL AND INTERNAL LEAFS OF CAVITY WALLS WITH 100mm CAVITY INCORPORATING SELECTED INSULATION, TO CONFORM WITH PART L OF THE BUILDING REGULATIONS 2005, FIXED WITH STAINLESS STEEL DOUBLE TRIANGULAR WALL TIES (TO IS 269: 1986) TO MANUFACTURERS INSTRUCTIONS, WITH RENDER FINISH TO EXTERNAL LEAF, PAINTED TO MATCH EXISTING FINISH.


CATNIC LINTOLS OR SIMILAR TO ALL WINDOW AND DOOR OPENINGS WITH CAVITY TRAY DPC ABOVE AND VERTICAL DPC TO BOTH JAMBS. WINDOW CILLS WITH DPC TO BASE, BACK AND SIDES. ALL BLOCKWORK SHALL BE OF NATURAL AGGREGATE AND SHALL BE BEDDED AND JOINTED IN GAUGED MORTAR AND PROPERLY BONDED AT INTERSECTIONS AND ANGLES.

ROOF CONSTRUCTION:

MAIN ROOF TO HAVE SELECTED CONCRETE TILES (COLOUR OF FINISH TO MATCH EXISTING MAIN ROOF), BONNET HIPS TILES AND LEAD TO VALLEY GUTTERS ON, 50X25mm S/W TANALISED BATTENS ON, "BLIZZARD" OR SIMILAR ROOFING FELT ON CUT TIMBER ROOF JOISTS AT 400mm CENTRES WITH 28.2 DEGREE PITCH. ROOF TIMBERS TO BE STRAPPED TO WALLS AT 2m CENTRES AND TO BE FIXED TO 100X75mm WALL PLATE ON DPC. INSULATION IN ROOF SPACE TO CONFORM WITH PART L OF THE BUILDING REGULATIONS 2005.


ROCKWOOL ROLLBATTS INSULATION (OR SIMILAR) BETWEEN ROOF MEMBERS SELECTED VAPOUR BARRIER FIXED TO STUDS 12.5mm PLASTERBOARD JOINTS TAPED AND SKIMMED.


VENTILATION OF ROOF SPACE TO CONFORM WITH PART F SECTION 2 OF THE BUILDING REGULATIONS 2002 TO GIVE AT LEAST EQUAL TO CONTINUOUS STRIP 25mm WIDE AT EAVES LEVEL, AT LEAST 50mm WIDE min. AIR GAP BETWEEN INSULATION AND UNDERLAY, AT LEAST EQUAL TO CONTINUOUS STRIP 5mm WIDE AT RIDGE LEVEL.

DOORS, WINDOWS & PERMANENT VENTILATION:

DOORS AND WINDOWS TO BE UPVC TO MATCH WITH PERMANENT VENTILATION


ALL VENTILATION TO CONFORM WITH PART F SECTION 1 OF THE BUILDING REGULATIONS 2002

GUTTER, DOWN PIPES, FASCIA & SOFFIT CONSTRUCTION:

UPVC DOWN PIPES & GUTTER TO MATCH EXISTING. GUTTER TO BE FIXED TO 240mm FASCIA. 125mm SOFFIT WITH CONTINUOUS 25mm CLEAR VENT TO ROOFSPACE, TO BE FINISHED AS FASCIA.

DPC's & DPM:

DPC TO EXTEND THROUGH THICKNESS OF EACH LEAF OF EXTERNAL WALL AND ALL INTERNAL WALLS AT MIN. OF 150mm ABOVE GROUND LEVEL AND TO BE CONTINUOUS & LAPPED WITH DPM.

INTERNAL SERVICES:

WATER, ELECTRIC AND CENTRAL HEATING INSTALLATIONS TO BE AS SPECIFIED BY SPECIALIST SUBCONTRACTORS.

EXTERNAL SERVICES:

SURFACE WATER DRAINS TO BE TAKEN TO MAIN SURFACE WATER TO LOCAL AUTHORITIES' APPROVAL.

Other Notes
DRYLINE EXISTING EXTERNAL WALL, TAPE, SKIM AND PREPARE FOR REQUIRED FINISH

REMOVE EXISTING PATIO DOOR AND MAKE GOOD EXISTING FINISHES WHERE REQUIRED

MAKE GOOD FLOOR FINISH WHERE EXISTING PATIO DOOR IS REMOVED WITH M.J. IN FLOOR



DPC & CAVITY TRAY WITH WEEP HOLES @900CNT.


NEW LIGHT WELL AND BULKHEAD


NEW RECESSED LIGHT FIXTURES IN CEILING,FIXTURE TYPE TO BE CONFIRMED BY CLIENT


NEW FLOOR FINISH TO BE CONFIRMED BY CLIENT


NEW PAINT FINISH TO BE CONFIRMED BY CLIENT

LEAD FLASHING DRESSED OVER NEW ROOF WITH MIN 150. UPSTAND AND CUT INTO EXISTING WALL 25mm MIN. MAKE GOOD EXISTING EXTERNAL FINISH AS REQUIRED.



NEW ROOF LIGHT, VELUX OR SIMILAR, SIZE 900mm WIDE x 1200mm LONG
 
CONNECT NEW RAIN WATER DOWN PIPE & AJ GULLY TO EXISTING SURFACE WATER MANHOLE

MAKE GOOD EXISTING EXTERNAL FINISHES WHERE REQUIRED